Controller DULCOMETER D1Cb/D1Cc

Controller
Model
Scope of application
Terms of trade
Download PDF
Promint Fluid Control (Shanghai) Co., LTD
Membership category
General Supplier
Seller category
Spare parts

The water analysis workhorse

The D1Cb/D1Cc controller is a 1-channel P/PID controller for the measured variables pH, ORP, chlorine, chlorine dioxideChlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ...more in the glossary, chlorite, ozone, bromine, peracetic acidhydrogen peroxideDue to its complete biodegradability, hydrogen peroxide is a disinfectant and oxidising agent ...more in the glossary, fluoride, dissolved oxygen and conductivity via mA. The sensors for pH and ORP can be directly connected via coaxial cable or using the 4-20 mA sensor input. The controller can bidirectionally control the measured variables, monitor limit values and transmit the measured value via an mA output, e.g. to a PLC Programmable Logic Controller. The mA output can optionally also be configured as an interference variable output. The controller has two pulse frequency outputs to control two metering pumps (raise and lower). Two output relays can optionally be used as limit value relays or to control motor-driven pumps or solenoid valves. An alarm relay signals the occurrence of a fault. A digital input is used to switch off the control or to process a sample water limit contact by remote control. The impact of temperature on the measurements can be provided by temperature measurement or by manual input. Menu-driven operation is possible in 20 languages.

Your benefits

  • Flexibility through free selection of variables from all measured variables
  • Safety through sensor monitoring of pH for glass breakage and line breakage
  • Flexibly upgradable, thanks to subsequent activation option of functions by means of an activation code
  • Various installation options: wall-mounted or installation in a control cabinet

Technical Details

  • Measured variables: pH, ORP, chlorine, chlorine dioxide, chlorite, bromine, conductivity, peracetic acid, hydrogen peroxide, ozone, dissolved oxygen and fluoride
  • Method of installation, degree of protection: D1Cb wall mounting IP 65, D1Cc control panel mounting IP 54, 1/4 DIN
  • Measurement: 1 measuring channel, temperature compensation for pH
  • Control: PID controller, bidirectional controller (e.g. with pH acid and alkali)
  • Control inputs: 1 digital control input

Technical Data

 

Measuring range

Connection type mV:
pH 0.00 … 14.00
ORP - 1000 … +1000 mV

Connection type mV:
Chlorine: 0.00...0.500/2.00/5.00/10.0/20.0/50.0/100.0 ppm
Chlorine dioxide: 0.00...0.500/2.00/10.0/20.0 ppm
Chlorite: 0.02..0.50/0.1...2 ppm
Bromine: 0.02...2.0/0.1...10.0 ppm
Ozone: 0.00...2.00 ppm
Hydrogen peroxide only with sensor PER1: 2.0...200.0/20...2000 ppm
Peracetic acid: 1...20/10...200/100...2000 mg/l
Dissolved oxygen: 0.1...10/0.1...20 ppm
pH: 0.00...14.00
ORP: 0...+1000 mV
Conductivity: 0...20/200/1000 mS/cm via mA transducer
Temperature: 0...100 °C via mA transducer

 